Separate names with a comma.
Ema rolled 400,000 miles a couple of weeks ago and is now at 403,6XX. The last 10,000 miles or so have been interesting and I thought I had lost...
Mendel, Do you know what the XGauge is for the fan speed? I can't seem to find it on ScanGauge XGauge list that I downloaded and printed out. I...
Bisco, I assume you mean the fan squirrel cage itself? Yes it was clean as were the various plastic ducts. You wouldn't happen to know what the...
This is great information THANKS!!!! I actually just sent my ScanGauge in to be upgraded this week so I can add these XGauges to monitor Ema. I...
Patrick, I tore into Ema last night and checked out the cooling fan area. The plastic slip pieces are fairly tight but I did add some duct tape...
Sorry to revise this thread but this happened to Ema as well but was originally the P0A84 battery fan low voltage error. I had Toyota fix the...
Ok, Ema threw a code on a trip to Florida and checking it is was the P0A82 code for the "Cooling Fan Stuck Off" or something like that. The weird...
R-P, Here is an old thread about Cruise Control Blinking: Cruise control light blinking | PriusChat I posted in that one and eventually found...
[ATTACH] [ATTACH] Here are the photos I promised. The top photo is simply an overview of the BM1 connector point. It is to the right of the...
Update on Ema, Ok, after I was frustrated with the online manual and tired of troubleshooting myself I took Ema to my dealer here in NC. Left the...
Ed, No software module, no battery issue. All the modules are within .1 V and all internal resistances are the same at 0.019. Battery is in good...
Patrick, Thanks, I forgot to disconnect it before I went. Was ticked off over the manual so just drove there. I did talk to the Tech who will be...
Patrick, Ok, so the online manual at TIS is wrong apparently. Your way the relay checks as good and I hear it click. Re-installed it back into...
Patrick, The repair manual says across 1-2 should be less than 1 ohm? Above 10 ohms for 3-5 without power on 1-2 then below 1 ohm on 3-5 with...
Patrick I did. 163 ohms across 1-2 so I know its bad. Trying to find the part# now so I can look for it locally and maybe avoid Toyota. Chris
Patrick, I signed up for the 2 day access and looked at the POA84 troubleshooting. The cooling fan relay is now checking as bad. I don't know if...
EricBecky, The grid charger box sits on a shelf in my garage when not in use. I actually purchased the Amphenol plug to cover the end of the...
Patrick, As always. THANKS!!!!!! You rock. The resistance thing was also were I am leaning as well. One VERY LARGE possibility I forgot to...
399,714 ... and counting (y)
Reviving an old thread here because Ema threw the 2 codes listed here on my way home from the mountains of North Carolina. She is giving both the...