Gen 3 HV cooling fan motor: wiring diagram?

Discussion in 'Gen 3 Prius Technical Discussion' started by priusb78, Sep 28, 2017.

  1. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    Hi!
    Is there chance to run the Gen 3 HV cooling fan motor on the bench?
    It has 4 wires which I don't know how to connect (Gen 2 with the 2 wires is simple... ;-)).
    Does anyone have a wiring diagram?
    Which signals / voltages does it need at which pin to run the motor?
    Any other thoughts?

    Thanks,
    Thorsten
     
  2. Vitos77

    Vitos77 Junior Member

    Joined:
    Oct 15, 2017
    2
    0
    0
    Location:
    Michigan
    Vehicle:
    2014 Prius v wagon
    Model:
    III
    wondering about the same, did you ever figure it out?
     
  3. Elektroingenieur

    Elektroingenieur Senior Member

    Joined:
    Jan 8, 2017
    2,515
    3,268
    9
    Location:
    California
    Vehicle:
    2016 Prius
    Model:
    Three Touring
    Toyota’s Repair Manual has a circuit description, wiring diagram, connector pinout information, and suggested troubleshooting procedure in the section for DTC P0A84-123, “Hybrid Battery Pack Cooling Fan 1.” The Repair Manual is available by subscription to techinfo.toyota.com (U.S.) or toyota-tech.eu (Europe); it may also be available at no charge through your local public library, if they subscribe to the ChiltonLibrary database.

    With the vehicle wire harness disconnected, connector S14 on the battery cooling blower assembly (with male terminals) looks a bit like this:
    Code:
               |---|
             +-+-+-+-+
        VM0  | 2 | 1 |  IG0
             +---+---+
       GND0  | 4 | 3 |  SI0
             +---+---+
    In normal operation, GND0 is connected to body ground and IG0 is connected to the 12-volt supply via the BATT FAN relay and fuse. SI0 is a speed signal from the Power Management Control ECU, and VM0 is a voltage monitoring signal to the Battery Smart Unit.

    The Repair Manual suggests using a service wire to connect SI0 and GND0, which should cause the fan to operate; I don’t see why that wouldn’t work on a bench, too. There is also an active test function for the fan in Toyota’s Techstream (GTS) diagnostic system: Under Powertrain > Hybrid Control > Active Test > Driving the Battery Cooling Fan, you can supposedly select any of the six air volume modes.
     
    edu4prius, Athos and m.wynn like this.
  4. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    m.wynn and Elektroingenieur like this.
  5. Vitos77

    Vitos77 Junior Member

    Joined:
    Oct 15, 2017
    2
    0
    0
    Location:
    Michigan
    Vehicle:
    2014 Prius v wagon
    Model:
    III
    Yes works like a charm with PC power supply
    [​IMG]
     
  6. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    Good! :)
    I use a lab power supply and can adjust the fan speed by amps applied.
     
  7. 2GenPrius

    2GenPrius Member

    Joined:
    Jun 2, 2018
    171
    32
    22
    Location:
    Californication
    Vehicle:
    2012 Prius
    Model:
    N/A
    I don't have access to the repair guide, and sorry for bumping an old post, but what are the color wires for each of the connectors? Found it after doing some searching around online.

    I have G9230-47020, which is the original version (before revision).

    Wire/Stripe:
    White/Black: #4
    Black/Yellow:#1
    Green/Red:#3
    Green/Black:#2
     
    #7 2GenPrius, Oct 20, 2020
    Last edited: Oct 20, 2020
  8. vjekobalas

    vjekobalas Junior Member

    Joined:
    Aug 18, 2021
    36
    4
    0
    Location:
    Croatia
    Vehicle:
    Other Hybrid
    Model:
    N/A
    I have the attached blower motor in a 2013 European Yaris - connector S14 on the battery cooling blower assembly (with male terminals) wires are same color at following pins (1=red, 2= white, 3=blue, 4= black) - does anyone know whether the pinout is the same ?
     

    Attached Files:

  9. ECOgarage

    ECOgarage New Member

    Joined:
    Apr 12, 2022
    5
    4
    0
    Location:
    91761
    Vehicle:
    2012 Prius
    Model:
    Five
    Anyone know how many amps this thing will pull on full speed? I highly doubt I'll be very much, just curious. I'll find out today either way. I found an old 12 volt power supply for some lights that I'm just going to use. Tops out at 3amps.
     
  10. ECOgarage

    ECOgarage New Member

    Joined:
    Apr 12, 2022
    5
    4
    0
    Location:
    91761
    Vehicle:
    2012 Prius
    Model:
    Five
    3amps didnt cut it. I ordered a 12v 10a power supply that wll be more than enough.
     
  11. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    At 14,7 V it is 2,0 A. At 12,0 V it is 1,7 A.
     
  12. Shadyghabboun

    Shadyghabboun New Member

    Joined:
    Jun 16, 2022
    5
    3
    0
    Location:
    Amman
    Vehicle:
    2015 Prius c
    Model:
    Two
    Hi All

    I know this is an old thread however I need help in operating my battery fan , so I connected the IG0 to +12V PSU and the GND0 to the -Ve terminal of the PSU , when I connect SI0 to the GND0 (i.e to the -ve terminal of the PSU) the fan does not operate at all, can any one advise how can I solve this matter ?

    Thanks in advance
     
  13. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    For connecting on the bench just using a power supply or 12 V-battery it is simple:

    upload_2022-6-17_8-24-42.png
     
  14. Shadyghabboun

    Shadyghabboun New Member

    Joined:
    Jun 16, 2022
    5
    3
    0
    Location:
    Amman
    Vehicle:
    2015 Prius c
    Model:
    Two
    Thank you for your prompt reply ,

    i did the wiring in the schematic however the fan starts and stops, and does not keep running, any idea why its doing this strange behavior?
     
  15. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    That's strange! What do you use as power supply?
     
  16. ASRDogman

    ASRDogman Senior Member

    Joined:
    May 29, 2018
    6,424
    3,413
    0
    Location:
    Florida
    Vehicle:
    2010 Prius
    Model:
    Two
    Perhaps, the fan is bad??? (n):whistle:

     
  17. priusb78

    priusb78 Member

    Joined:
    Jul 20, 2009
    52
    46
    0
    Location:
    Nuremberg, Germany
    Vehicle:
    2005 Prius
    Model:
    II
    Could be! But who has a second one to check? ;-)

    To run my Gen 3 fan on the bench (for battery charging) I use a power supply where I can set voltange and current. With 12 - 14 Volts and 1 - 3 Amps the fan runs well.
     
  18. ASRDogman

    ASRDogman Senior Member

    Joined:
    May 29, 2018
    6,424
    3,413
    0
    Location:
    Florida
    Vehicle:
    2010 Prius
    Model:
    Two
    If you hook up a 12v battery, that charged and know good, and the fan does
    the same thing, you're confirming it is manfunctioning.
    It is possible that I may be incorrect. But I don't believe it should do as you are stating
    when you put 12volts directly to it.
     
  19. ECOgarage

    ECOgarage New Member

    Joined:
    Apr 12, 2022
    5
    4
    0
    Location:
    91761
    Vehicle:
    2012 Prius
    Model:
    Five
    I just wanted to jump in, this site has been a huge resource for all of us. My buddies and I work on our rental fleet of Prius, and in order to maintain our hybrid batteries, I've built two "sleds" that I use to test batteries before running them through the prolong and then reassembling.

    I have used a 12v 10amp power supply on the same 2 fans the entire time. Neither fan has failed. One power supply exploded tho haha.