1. Attachments are working again! Check out this thread for more details and to report any other bugs.

Poll: What 240v Receptacle Do You Have ?

Discussion in 'Prime Plug-in Charging' started by Rob43, May 14, 2019.

?
  1. 10-30R

    1 vote(s)
    4.5%
  2. 10-50R

    2 vote(s)
    9.1%
  3. 14-30R

    2 vote(s)
    9.1%
  4. 14-50R

    8 vote(s)
    36.4%
  5. 6-20R

    3 vote(s)
    13.6%
  6. Other

    6 vote(s)
    27.3%
  1. Rob43

    Rob43 Senior Member

    Joined:
    Sep 24, 2014
    1,373
    1,048
    0
    Location:
    VA, BMW Race Car, BMW R1200R, BMW 330Ci, Ford F350
    Vehicle:
    2013 Prius v wagon
    Model:
    Prime Advanced
    What 240v receptacle do you have (if any) that's located close enough for car charging ?


    Rob43
     
  2. Tha_Ape

    Tha_Ape Active Member

    Joined:
    Apr 9, 2019
    271
    161
    0
    Location:
    Washington, DC
    Vehicle:
    2017 Prius Prime
    Model:
    Plug-in Advanced
    I've got 2

    A NEMA 6-50 (50A) and a NEMA 6-20 (20A).
    I use the 6-20, so that's what I voted in the poll.

    A welder used to live here so I got outlets galore. Made no sense to use the 6-50 since the car maxes out at 16A. The 20A outlet seemed more appropriate. If I ever get a 100% EV, I'll use the other outlet.
     
    Rob43 likes this.
  3. John321

    John321 Senior Member

    Joined:
    Nov 16, 2018
    1,285
    1,276
    0
    Location:
    Kentucky
    Vehicle:
    2008 Prius
    Model:
    Two
    Rob43 I am adding a new circuit for my level 2 charger in my garage. I am going to hard wire it in when I run the new circuit. I have done electric work most of my life and will be doing it myself.

    I would like to remind people to be sure to buy a safety certified unit that is UL listed. A professional electrician will not wire in or work on a Level 2 charger that isn't listed by UL. There is a liability issue if there were personal injury or structural damage caused by a unit malfunction and he had worked on it. There can also be a possibly insurance problem if structure damage was caused by a homeowner installing a non UL listed device.
    Here is a wonderful video talking about Level 2 and car chargers in general. You will find this Manufacturer has many informative videos on this subject. I am not trying to hijack this thread but saw it as an opportunity to provide a possible resource to people as well as respond to the survey.
    Here is the video

    ClipperCreek Goes Through Time, Expense for Safety
     
    #3 John321, May 15, 2019
    Last edited: May 15, 2019
    ETC(SS) likes this.
  4. Rmay635703

    Rmay635703 Senior Member

    Joined:
    Oct 16, 2016
    2,609
    1,624
    0
    Location:
    Somewhere in Wisconsin
    Vehicle:
    2013 Chevy Volt
    Model:
    N/A
  5. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    110,156
    50,059
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    i have the 14-30r rotate to lock
     
  6. Diemaster

    Diemaster Active Member

    Joined:
    Oct 31, 2017
    290
    260
    2
    Location:
    so. cal
    Vehicle:
    2017 Prius Prime
    Model:
    Prime Advanced
    I put other. I have a 30A circuit in the garage. I put on a 14-50 outlet for my bigboy EVSE. Then I bought a RV and that outlet went to that use. Now i charge nightly over 6 hours.
     
  7. CharlesH

    CharlesH CA HOV Decal #5 on former PiP

    Joined:
    Nov 27, 2005
    2,788
    1,153
    0
    Location:
    Roseville, CA
    Vehicle:
    2017 Prius Prime
    Model:
    Prime Advanced
    NEMA 6-50, since that is what the 32A Chargepoint Home charging station wanted. The breaker panel is on the other side of the garage wall from the outlet, so having an electrician install it up to code did not cost that much.
     
  8. Tideland Prius

    Tideland Prius Moderator of the North
    Staff Member

    Joined:
    Oct 2, 2004
    45,024
    16,244
    41
    Location:
    Canada
    Vehicle:
    Other Non-Hybrid
    Model:
    N/A
    6-50R. Not my favourite since it’s not as common.
     
  9. DavidA

    DavidA Prius owner since July 2009

    Joined:
    Jul 14, 2009
    2,329
    1,812
    18
    Location:
    Chicago western burbs
    Vehicle:
    2017 Prius Prime
    Model:
    Prime Advanced
    [​IMG]
    The 240v 40A is a 14-50.
    The 120v 20A is my fallback if the 240 fails.

    I will add that wasps just love to build their nests right above the J1772 handle holder.
     
    #9 DavidA, May 19, 2019
    Last edited: May 19, 2019
  10. Elektroingenieur

    Elektroingenieur Senior Member

    Joined:
    Jan 8, 2017
    2,515
    3,268
    9
    Location:
    California
    Vehicle:
    2016 Prius
    Model:
    Three Touring
    The National Electrical Code (2017), at least as published by NFPA, doesn’t allow the use of locking receptacle outlets for electric vehicle charging:

    625.44 Equipment Connection. Equipment shall be connected to the premises wiring system in accordance with one of the following:

    (A) Portable Equipment. Portable equipment shall be connected to the premises wiring systems by one or more of the following methods:

    (1) A nonlocking, 2-pole, 3-wire grounding-type receptacle outlet rated at 125 volts, single phase, 15 or 20 amperes
    (2) A nonlocking, 2-pole, 3-wire grounding-type receptacle outlet rated at 250 volts, single phase, 15 or 20 amperes
    (3) A nonlocking, 2-pole, 3-wire or 3-pole, 4-wire grounding-type receptacle outlet rated at 250 volts, single phase, 30 or 50 amperes
    (4) A nonlocking, 2-pole, 3-wire grounding-type receptacle outlet rated at 60 volts dc maximum, 15 or 20 amperes

    The length of the power supply cord, if provided, between the receptacle outlet and the equipment shall be in accordance with 625.17(A)(3).

    (B) Stationary Equipment. Stationary equipment intended to be fastened in place in such a way as to permit ready removal for interchange, facilitation of maintenance or repair, or repositioning shall be connected to the premises wiring system by one of the following methods:

    (1) A nonlocking, 2-pole, 3-wire grounding-type receptacle outlet rated 125 volt or 250 volt, single phase, up to 50 amperes
    (2) A nonlocking, 3-pole, 4-wire grounding-type receptacle outlet rated 250 volt, three phase, up to 50 amperes
    (3) Any of the receptacle outlets in 625.44(A)(1) or (2)

    The length of the power supply cord, if provided, between the receptacle outlet and the equipment shall be in accordance with 625.17(A)(3).

    (C) Fixed Equipment. All other equipment shall be permanently wired and fixed in place to the supporting surface.

    There is are charts of the non-locking and locking plug/receptacle configurations towards the end of ANSI/NEMA WD 6, Wiring Devices—Dimensional Specifications. Collect them all!
     
  11. DavidA

    DavidA Prius owner since July 2009

    Joined:
    Jul 14, 2009
    2,329
    1,812
    18
    Location:
    Chicago western burbs
    Vehicle:
    2017 Prius Prime
    Model:
    Prime Advanced
    ^ Well, that's interesting. My (licensed) electrician wouldn't install it without those outlet covers since they were outside the house and subject to possible water intrusion. If he knew about this provision, he might have just used an outlet box he had available. I don't have to lock the actual plug, since the EVSE itself is installed with a lockable bracket to prevent theft.
     
    #11 DavidA, May 19, 2019
    Last edited: May 19, 2019
  12. Elektroingenieur

    Elektroingenieur Senior Member

    Joined:
    Jan 8, 2017
    2,515
    3,268
    9
    Location:
    California
    Vehicle:
    2016 Prius
    Model:
    Three Touring
    That’s correct: the outlet covers are required by the Code in damp or wet locations (see 406.9 and 625.56). If a cover is designed to accept a security lock, I see nothing wrong with using one, if you wish.

    “Nonlocking” in 625.44 refers to the receptacle configuration: straight-blade devices, as in your photo, are permitted, but the kind that turn to lock in place, such as those sold by Hubbell under the Twist-Lock brand, aren’t allowed, at least in jurisdictions that have adopted the Code without amending that section.
     
  13. DavidA

    DavidA Prius owner since July 2009

    Joined:
    Jul 14, 2009
    2,329
    1,812
    18
    Location:
    Chicago western burbs
    Vehicle:
    2017 Prius Prime
    Model:
    Prime Advanced
    ^ OK, thanks for the additional and very detailed information. The covered kind was what I requested when we spec'd out the install. Didn't know there were options other than covered or not covered.
     
    Elektroingenieur likes this.
  14. John321

    John321 Senior Member

    Joined:
    Nov 16, 2018
    1,285
    1,276
    0
    Location:
    Kentucky
    Vehicle:
    2008 Prius
    Model:
    Two
    DavidA your electrician was smart putting a cover on the units. Water has a way of getting in to things especially outside, in or around a garage where water is often used.It looks from your installation that you had a conscientious one doing your work!
     
  15. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    110,156
    50,059
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    mine came with the curved plug, so i installed the curved outlet. i wonder what their reasoning is.
     
  16. Rmay635703

    Rmay635703 Senior Member

    Joined:
    Oct 16, 2016
    2,609
    1,624
    0
    Location:
    Somewhere in Wisconsin
    Vehicle:
    2013 Chevy Volt
    Model:
    N/A
    Considering every electric car (even my fathers 2005 Zx40) have a charger interlock disabling motion I don’t see a good reason to disallow a plug that doesn’t fall out of the socket, unless they figure the weight of the evse on the cable could damage the connection?

    All sounds very silly, sort of like it being perfectly fine for 110vac wiring to have a rated current breaker that matches the wire rating but may not match the outlets rating,
    While on 220 the practice is disallowed even when outlets are ganged to a single breaker

    Mental masturbation at its best
     
  17. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    110,156
    50,059
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    mine is a permanent mounted install, just not hard wired. i wonder if there are portables with a curved plug.
     
  18. jb in NE

    jb in NE Senior Member

    Joined:
    Apr 13, 2018
    2,233
    1,596
    0
    Location:
    Nebraska
    Vehicle:
    2018 Prius Prime
    Model:
    Prime Premium
    It's required by the code to have a water cover on exterior outlets. Being a licensed electrician, and given that in most jurisdictions this type of work requires a permit, he follows the code. The newer codes assume the outlet will be in use during rain and require the newer covers that allow the cord to be plugged in while the outlet remains covered.
     
  19. bisco

    bisco cookie crumbler

    Joined:
    May 11, 2005
    110,156
    50,059
    0
    Location:
    boston
    Vehicle:
    2012 Prius Plug-in
    Model:
    Plug-in Base
    plus, with gfi, a little moisture easily confuses them.
     
  20. JimboPalmer

    JimboPalmer Tsar of all the Rushers

    Joined:
    Apr 14, 2009
    12,470
    6,871
    2
    Location:
    Greenwood MS USA
    Vehicle:
    2012 Prius v wagon
    Model:
    Three