1. Attachments are working again! Check out this thread for more details and to report any other bugs.

Displaying SOC and BTA on Scangauge

Discussion in 'Prius PHEV Plug-In Modifications' started by kiettyyyy, Nov 8, 2009.

  1. kiettyyyy

    kiettyyyy Plug-In Supply Engineer

    Joined:
    Sep 17, 2008
    205
    167
    0
    Location:
    West Covina, CA
    Vehicle:
    2009 Prius
    Model:
    N/A
    Hey all,

    I've seen many photos with other individuals setting up their Scangauges to display both SOC and BTA on the same screen(at the same time).

    How do you do this?

    If tell my Scangauge to display SOC and BTA, only SOC will show and the BTA will be blank.

    It only displays one at a time.

    Any ideas?

    Thanks!
     
    1 person likes this.
  2. kiettyyyy

    kiettyyyy Plug-In Supply Engineer

    Joined:
    Sep 17, 2008
    205
    167
    0
    Location:
    West Covina, CA
    Vehicle:
    2009 Prius
    Model:
    N/A
    Actually, I think I just figured it out..

    I have to use the Passive gauges, right?
     
    1 person likes this.
  3. kaval

    kaval New Member

    Joined:
    Feb 5, 2004
    3
    0
    0
    Can you tell me how to do this please?
     
  4. Floyd2

    Floyd2 progressio per sententia

    Joined:
    Aug 23, 2009
    106
    23
    0
    Location:
    Netherlands, Europe
    Vehicle:
    2006 Prius
    Model:
    II
    If two gauges have the same TXD value they will collide. So if you use 07E321CE for BTA then don't use the 07E321CE TXD for SOC. They will interfere and one of the two will not be shown.

    Instead, use a passive request for the SOC at TXD: 03C3.

    So enter these settings for SOC instead:
    TXD 03C3
    RXF 010382CB0000
    RXD 2010
    MTH 000A00020000
    NAM SOC

    Now you can watch BTA and SOC simultaniously. :)

    Good luck! Floyd
     
    2 people like this.
  5. epa5epa

    epa5epa Junior Member

    Joined:
    Aug 9, 2008
    28
    3
    0
    Location:
    Taiwan
    Vehicle:
    2008 Prius
    I am wonder why my Soc is blank along with Bta today till I find Floyd's posting.

    A friend in need is a friend indeed.

    Thanks! Floyd
     
  6. kiettyyyy

    kiettyyyy Plug-In Supply Engineer

    Joined:
    Sep 17, 2008
    205
    167
    0
    Location:
    West Covina, CA
    Vehicle:
    2009 Prius
    Model:
    N/A
    About a month ago, I spoke with Ron and James from Linear Logic regarding same RXF addresses. Currently, if two xgauges contain the same RXF match data (bytes 2 and 4, 1 and 3 are used for determining which byte in the message to match), the xgauge(arbitrarily determined) is executed first will "steal" away any data with the same RXF match from any other xgauge.

    According to Linear Logic, this will be taken care of in the next firmware release.

    Can't wait to view my custom CAN data :)

    -Kiet
     
    1 person likes this.